Intergrated Network Switching Power Supply

MODELZDPS-S60/120/240/360/-12

Facebook Twitter InLink instagram Youtube Skype
  • IP20 design for indoor

  • Built-in EMI filter

  • Accurate and stable output voltage

  • Output over-voltage, over-current and short-circuit protection

  • Average no trouble working>20,000 hours

  • In line with world lighting safety regulations

Intergrated Network Switching Power Supply:  DC12V, 15W~500W optional, it is widely used for all kind of LED lighting, Solar energy system, building automation, medical equipment, PLC control system, Intelligent robot and LED screen etc 

Built-in EMI filter 
- 100% Load burn-in test
- Wide range of input voltage
- Accurate and stable output voltage
- Output over-voltage, over-current and short-circuit protection
- Low output ripple and noise
- Average no trouble working>20,000 hours

ModelItemsZDPS-S60-12ZDPS-S120-12ZDPS-S240-12ZDPS-S360-12
OutputDC Voltage12V
Rated Current5A10A20A30A
Current Range0~5A0~10A0~20A0~30A
Rated Power60W120W240W360W
Ripple & Noise (max.)120mVp-p
Voltage Tolerance±2.0%±2.0%±2.0%±2.0%
InputVoltage Range110~240VAC 
Frequency Range50~60HZ
Efficiency(Typ.)82%
AC Current (Typ.)2.3A/240VAC  or  5.5A/110VAC
Inrush Current (Typ.)Cold strart 60A/220VAC
ProtectionOver LoadOverload protected   @110~160% above peak rating
Over TemperatureProtection type: Shut down O/P,re-power on to   recover
Short circuitProtection type:   recovers automatically after fault condition is removed
EnvironmentWorking Temperature -30~+50°C  (Refer   to output load derating curve)
Working Humidity20~80% RH  Non-condensing(Non   Waterproof)
Storage temp.& humidity-30~+40°C, 10~80%RH
Safety & EMCSafety StandardsCE,RoHS, FCC
Withstand VoltageI/P-O/P:1.5KVAC   I/P-GND: 1.5KVAC
EMC Test StandardsEN55015:2013,   EN61000-3-2: 2014
Note1. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 10uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.


Package Contents: 

  • Standard Exporting Packing Box